VRF/VRV

Outdoor VRF

  • RANGE MINIMUM (4HP) 3.2 TR TO MAXIMUM (6HP) 4.8 TR
  • COMPACT – space saving (Industries Compact in Size as well as lightest in weight).
  • Efficient & high performance 100% Inverter type Compressor.
  • Industry Bests Coefficient of Performance (COP)
  • Operates on environment friendly refrigerant R-410A

Outdoor VRF

  • RANGE MINIMUM (8HP) 6.4 TR TO MAXIMUM (12HP) 9.6 TR
  • DESIGN FLEXIBILITY- suitable for large as well as Small sized buildings.
  • Industries Leading Total Piping length up to 510m.Higher external static pressure for condenser fans Automatic test operation function

Outdoor VRF

  • RANGE MINIMUM (12HP) 9.8 TR TO MAXIMUM (48HP) 38.4 TR
  • MEMORY FUNCTION – Eliminate malfunctions.
  • Industries Leading Total Piping length up to 1000m.
  • High combination ratio (Indoor unit vs. Outdoor unit)
  • Compatible with building management control system – optional.

INDOOR VRF

Indoor VRF

CEILING CASSETTE (4 WAY ) TYPE:

  • MODEL NO : FDT28, FDT36, FDT45, FDT56, FDT71, FDT90, FDT112, FDT140, FDT160.
  • QUIET SOUND LEVEL : As low as 30 dB(A)
  • RANGE : 0.8 TR to 4.6 TR
  • INDIVIDUAL FLAP CONTROL SYSTEM : According to room temp. Conditions, four directions of air flow can be controlled by individual flap as preferred. As individual flap contol is available even after installation, area became wider than before.
  • INBUILT DRAIN PUMP : Water lift-up mechanism.
  • THINNEST DESIGN : Thanks to new design of heat exchanger from 2 parts to 1 part, the height of indoor unit is reduced drastically.

Indoor VRF

CEILING CASSETTE (4 WAY ) COMPACT TYPE (600X600) :

  • MODEL NO: FDTC15, FDTC22, FDTC28, FDTC36, FDTC45, FDTC56
  • RANGE: 0.4TR to 1.56TR
  • COMPACT IN SIZE – Corresponds with 600mm x 600mm architectural module ceiling design.
  • COMFORTABLE AIRFLOW – Wide variation of choice Built- in condensate drain pump
  • INDIVIDUAL FLAP CONTROL SYSTEM : According to room temp. Conditions, four directions of air flow can be controlled by individual flap as preferred. As individual flap control is available even after installation, area became wider than before

Indoor VRF

CEILING CASSETTE (2 WAY)

  • MODEL NO: FDTW28, FDTW45, FDTW56, FDTW71, FDTW90, FDTW112, FDTW140
  • RANGE: 0.8 TR to 4.0 TR
  • TRANSPARENT ACCESS HOLE TO DRAIN PAN: Dirt condition of the bottom of a drain pan can be checked through this transparent access hole without removing drain pan. BUILT- IN condensate drain pump.

Indoor VRF

CEILING CASSETTE 1 WAY TYPE:

  • MODEL NO: FDTS45, FDTS71
  • RANGE: 1.28TR & 2.0TR
  • COMPACT IN SIZE – Height of the machine is 220mm only.
  • Built- in condensate drain pump

Indoor VRF

CEILING CASSETTE 1 WAY COMPACT:

  • MODEL NO: FDTQ22, FDTQ28, FDTQ36
  • RANGE: 0.6 TR to 1.0 TR
  • COMPACT IN SIZE – Corresponds with 600mm x 600mm architectural module ceiling design
  • COMPACT DESIGN: Comfortable effective cooling for small rooms, with low fan speed airflow at just 5.4 cubic meter per minute
  • BUILT- IN: condensate drain pump

Indoor VRF

DUCT CONNECTED- HIGH STATIC PRESSURE:

  • MODEL NO: FDU45, FDU56, FDU71, FDU90, FDU112, FDU140, FDU160, FDU224, FDU280
  • EXTERNAL STATIC PRESSURE CONTROL: External static pressure (E.S.P.) can be increase or decrease in wired remote control
  • REDUCTION OF WEIGHT: 6 kg less weight than previous models
  • REDUCTION OF SOUND PRESSURE LEVEL: 8 DB less noise than previous models.
    WIDE RANGE: 1.6 TR to 8.4 TR
  • STATIC ADVANTAGE: Availability in a wide range of 50 to 200 pascals. Ideal for Hotel & Apartment Applications

Indoor VRF

DUCT CONNECTED- LOW/MIDDLE STATIC PRESSURE

  • MODEL NO: FDUM22, FDUM28, FDUM36, FDUM45, FDUM56, FDUM71, FDUM90, FDUM112, FDUM140, FDUM160
  • DESIGN FLEXIBILITY: Expansion of external static pressure
  • WIDE RANGE: 0.6 TR to 4.6 TR
  • THIN DESIGN: The height of all FDUM models is only 280 mm
  • STATIC ADVANTAGE: Availability in a wide range of 50 to 200 pascals. Ideal for Hotel & Apartment Applications

Indoor VRF

DUCT CONNECTED (THIN)- LOW STATIC PRESSURE

  • MODEL NO: FDUT15, FDUT22, FDUT28, FDUT36, FDUT45, FDUT56, FDUT71
  • QUIET SOUND LEVEL : As low as 25 dB(A)
  • RANGE : 0.4 TR to 2.0 TR

Indoor VRF

DUCT CONNECTED (COMPACT & FLEXIBLE)

  • MODEL NO: FDUH22, FDUH28, FDUH36
  • WIDE RANGE: 0.6 TR to 1.0 TR
  • THIN DESIGN & LIGHT WEIGHT: The height of all FDUH models is only 257 mm & Weight is only 20 kg
  • Ideal for Hotel & Apartment Applications

Indoor VRF

Wall Mounted Type:

  • Model No: FDK22, FDK28, FDK36, FDK45, FDK56, FDK71
  • Low Operation Sound Level: Sound Level as low as 31 dB(A)
  • Range : 0.6 TR to 2 TR
  • Innovative Design: New FDK model adopts the air flow design that’s proven to minimise resistance in a CFD analysis to achieve uniform air conditioning to the furthest corners of the room. Flap Control System: Selection of flap position is possible, a flap can be set as different angles

Indoor VRF

CEILING SUSPENDED

  • MODEL NO: FDE36, FDE45, FDE56, FDE71, FDE112, FDE140
  • RANGE: 1.0 TR to 4.0 TR
  • FLAP CONTROL SYSTEM: Selection of flap position is possible. A flap can be set as different angles
  • SLIM DESIGN: Slim & Sleek Design Starting at just 28 kg in weight means quick, easy & neat installation
  • INSTALLATION WORK ABILITY: Refrigerant Piping can be routed in 3 directions (rear up & right)

Indoor VRF

FLOOR STANDING 2 WAY TYPE:

  • MODEL NO: FDFW28, FDFW45, FDFW56
  • Range : 0.8TR to 1.6TR
  • EASY MAINTENANCE – Front of unit
  • QUIET SOUND LEVEL : As low as 30 dB(A)
  • SOPHISTICATED DESIGN : Choice of wall hanging, floor standing or behind gallery installation is available
  • FLAP CONTROL SYSTEM : Selection of flap position is possible. A flap can be set as different angles
  • CONVENIENT TO USE OPERATION : Simultaneous lower & upper air outlets or upper outlets can be selected by airflow direction button

Indoor VRF

FLOOR STANDING WITH CASING TYPE:

  • MODEL NO: FDFL71
  • RANGE : 2.0 TR
  • EASY MAINTENANCE – Front of unitCOMPACT DESIGNSuitable for perimeter zone air conditioning
  • QUIET SOUND LEVEL : As low as 30 dB(A) Ideal for big offices, shopping malls, banquet halls, RESIDENCE

Indoor VRF

FCONCEALED FLOOR STANDING TYPE (WITHOUT CASING):

  • MODEL NO: FDFU28, FDFU45, FDFU56, FDFU71
  • RANGE : 0.8TR to 2.0TR
  • Gives high class interior design. Installed in skirting wall of perimeter

Indoor VRF

OUTDOOR-AIR PROCESSING UNIT:

  • MODEL NO: FDU500, FDU850, FDU1300, FDU1800
  • RANGE : 2.6 TR TO 8.0 TR
  • COMBINES FRESH AIR TREATMENT & AIR-CONDITIONING SUPPLIED FROM SINGLE SYSTEM Air conditioning and outdoor air processing can be accomplished using a single system COMPACT DESIGN: Design at just 360 mm in height & high static pressure of 200 pa. Connectivity with outdoor unit 8 to 48 HP.

Indoor VRF

FRESH AIR VENTILATION AND HEAT EXCHANGE UNIT:

  • MODEL NO: SAF250, SAF350, SAF500, SAF650, SAF800, SAF1000
  • AIRFLOW (CUBIC METER PER HOUR): 250 to 1000
  • KEY FEATURES:Reduces Airconditioning load Easy installation in ceiling due to low heightNight time free cooling operation

Indoor VRF

FRESH AIR DX ASSEMBLY:

  • MODEL NO: SAF-DX250, SAF-DX350, SAF-DX500, SAF-DX650, SAF-DX800, SAF-DX1000
    AIRFLOW (CUBIC METER PER HOUR): 250 to 1000
  • KEY FEATURES INTERLOCKING WITH AC IDUSUPERLINK CONNECTION AVAILABLE Connectivity with all MHI KX6 outdoor unit.
  • Return Air Temperature Control or supply air temperature control can be selectable.

 

Variable Refridgerant Flow

Reduced overall
energy costs

Lower maintenance
Proper ventilation

VRF is the latest and most revolutionary technologies used for large, medium & small sized buildings. The system offers large outdoor capacities, greater energy savings, easier installation, longer actual and total piping, and more. VRF airconditioning units use refrigerant as the cooling & Heating medium.This refrigerant is conditioned by a single outdoor condensing unit, & is circulated with in the building.

The following is a list of some of the operational benefits:

VRF Units operated at varying speeds, VRF unit work only at the needed rate allowing for substantial energy saving at partial-load conditions. Energy Savings off upto 55% are predicted over comparable unitary equipment.

  • Energy savings of 55 to 60 percent
  • The air and water flows match the system demand
  • Fan noise is drastically reduced
  • Low installation cost and no mechanical fabrication